The grate under the catalytic combustor is cracked. Does this need to be replace immediately?

Sorry completely new to everything wood stove. But there's a pretty big crack in the grate looking thing under the catalytic converter. https://imgur.com/igsb578 and https://imgur.com/wjJj19R and https://imgur.com/a2yUO9l

I'm curious if it's okay to use this for the time being at the very least or if I should stop further usage until it can be replaced. Bonus: Is this easy to replace if so?

πŸ‘︎ 3
πŸ’¬︎
πŸ‘€︎ u/ItWillComeToUs
πŸ“…︎ Jan 17 2022
🚨︎ report
Retrofitting older stove with catalytic combustor - seeking advice

I have a Harman TLC 2000 coal/wood combo stove from the 90s. It's a decent stove, but I'd like to elongate burn times. Burning it low and slow leads to fast creosote build-up in my chimney, so I'm looking to retrofit it to be a catalytic stove. Its baffle design has two rectangular entry points (at the top of the chamber, one to the left and one to the right, both near the front). There's also a removable steel plate in the center that you can access by popping up the top of the stove and sliding the plate out.

My plan is to get catalytic converters which match the dimensions of the top left and right rectangular openings (2.25" x 6.75"). When I start the stove cold, I will remove the center bypass plate so it exhausts directly up the chimney until it's hot. I already have a thermocouple so I'll know when it reaches 500deg F (and the catalysts activate). The one downside I see is that I can't open the bypass plate without first opening the stove lid, so I wonder how much smoke will billow in for those 2 or 3 seconds before I can grab the plate to remove it (when stove is already underway). Has anybody done a retrofit before? Any advice?

πŸ‘︎ 3
πŸ’¬︎
πŸ‘€︎ u/Sub1ime14
πŸ“…︎ Jan 12 2022
🚨︎ report
Stimulate your combustor v.redd.it/0izfdf30dc781
πŸ‘︎ 180
πŸ’¬︎
πŸ‘€︎ u/ToyotaCorollin
πŸ“…︎ Dec 23 2021
🚨︎ report
I added a temperature readout to my Buck stove insert. The top number is the temperature of the catalytic combustor, the bottom number is the temperature inside the firebox. I simply replaced the thermometer that reads the combustor temperature with a $3 thermocouple and $15 readout from Amazon.
πŸ‘︎ 8
πŸ’¬︎
πŸ‘€︎ u/Gopherfarm7482
πŸ“…︎ Nov 11 2021
🚨︎ report
DRDO Pulse Detonation Engine Combustor at testing facility. PDE has better efficiency than Turbofan Engines. It can go from Subsonic to near hypersonic speeds. DRDO is working on this tech from many years. mobile.twitter.com/Varun5…
πŸ‘︎ 14
πŸ’¬︎
πŸ‘€︎ u/Blank_eye00
πŸ“…︎ Jan 12 2022
🚨︎ report
[Help] New to burning with a catalytic combustor. Having trouble getting temp >500 to close flue and engage. Model is an Appalachian Stove 36BW- any tips?
πŸ‘︎ 9
πŸ’¬︎
πŸ‘€︎ u/FuzzCanyonCowboy
πŸ“…︎ Nov 22 2021
🚨︎ report
Carrion Combustor [Workshop] steamcommunity.com/shared…
πŸ‘︎ 798
πŸ’¬︎
πŸ‘€︎ u/OverPovered
πŸ“…︎ Sep 04 2021
🚨︎ report
Catalytic combustors

Has anyone ever incorporated a wood stove catalytic combustor into their retort design to maximize the combustion of pyrolysis gases around the feedstock, rather than using an afterburner to clean up the gases exiting the chimney?

πŸ‘︎ 8
πŸ’¬︎
πŸ‘€︎ u/l94xxx
πŸ“…︎ Dec 18 2021
🚨︎ report
How it feels to Chew 5 kerosene: Stimulate your combustor v.redd.it/0izfdf30dc781
πŸ‘︎ 13
πŸ’¬︎
πŸ‘€︎ u/ToyotaCorollin
πŸ“…︎ Dec 25 2021
🚨︎ report
The fiery heart of the CFM56: the annular combustor ring, a core part of the engine; containing several fuel injectors. The air inlet holes around the injector seat are arranged to create a 'swirling' vortex which focuses the ignited air/fuel mix to turn the HP turbine. Powers 737/A320 + many more.
πŸ‘︎ 32
πŸ’¬︎
πŸ‘€︎ u/InterstellarFlyer
πŸ“…︎ Oct 28 2021
🚨︎ report
First time fire of the season for my 18 year old Buck Stove, Buckmaster Zero Clearance. Added new combustor and used inexpensive thermocouples to monitor the temperatures. Its fun to watch the combustor light up and quickly take off in temperature. This will run continuously until next April. reddit.com/gallery/qlh1c2
πŸ‘︎ 3
πŸ’¬︎
πŸ‘€︎ u/Gopherfarm7482
πŸ“…︎ Nov 02 2021
🚨︎ report
Anyone have problems with a new overactive catalytic combustor?

I'm getting crazy hot heat in the combustion chamber of my hearthstone heritage, and yet the firebox is a steady 400 degrees. I'm thinking I have an overactive combustor, but I'm just wondering if anyone else has had this problem? Is it something that will just work itself out over a cord of wood or so?

Edit and Solution! Turns out the temperature probe on the side of my stove should not directly touch the soapstone, but instead be about 1/8 - 1/4 inch pulled out. The heating soapstone was causing the probe to give false high temp readings. Thank you all who helped me with this!

πŸ‘︎ 4
πŸ’¬︎
πŸ‘€︎ u/P-Money
πŸ“…︎ Oct 29 2021
🚨︎ report
What is the speed of the hot gases exiting the combustor of a jet engine?

Are the hot gases from a combustor of a jet engine exiting at subsonic or supersonic speeds?

πŸ‘︎ 3
πŸ’¬︎
πŸ‘€︎ u/dragonmidnight
πŸ“…︎ Oct 29 2021
🚨︎ report
[COTD] Biomass Combustors | 6 Mars, 2021

Previous COTD

Today's card is Biomass Combustors (#183):

Automated card (Green) | Base game

Cost: 4 | Requirements: 6% oxygen | Tags: Power, Building

Decrease any plant production 1 step. Increase your energy production 2 steps. -1 VP

My thoughts: A very cheap way to get energy production while also harming a bit of an opponent's ground game. If you can snatch a city spot with the energy production and a city card, it's fine to suffer the -1 VP.

Next COTD

πŸ‘︎ 15
πŸ’¬︎
πŸ‘€︎ u/Enson_Chan
πŸ“…︎ Mar 06 2021
🚨︎ report
The combustor liner design of the J75/JT4A is a unique can-annular design. 8 cans with annular liners and 6 fuel nozzles each constitute the combustion section. (Description in the comments) reddit.com/gallery/m3cor5
πŸ‘︎ 6
πŸ’¬︎
πŸ“…︎ Mar 12 2021
🚨︎ report
Pyro Primary: The Combustor

Look: Old-fashioned blow-torch attached to the stock flamethrower's hose.

+On kill: Enemy drops a small gas canister that refuels your flamethrower by 20%.

+40% Larger flame particle spread.

-Does no damage to enemy Pyros.

-No airblast

-Mini-crits whenever it would normally crit

πŸ‘︎ 2
πŸ’¬︎
πŸ‘€︎ u/billcage32
πŸ“…︎ Apr 08 2021
🚨︎ report
Typical Mach number for Combustor exit/ Turbine inlet?

Anyone know any "rule of thumb" Mach numbers for this stage? This is for a turbojet flying at M=.85

πŸ‘︎ 11
πŸ’¬︎
πŸ‘€︎ u/Willben44
πŸ“…︎ Nov 22 2020
🚨︎ report
Figured I'd keep adding some fx to my Kastelans after all the great feedback. Here's my attempt at an Incedine Combustor!
πŸ‘︎ 242
πŸ’¬︎
πŸ‘€︎ u/likeitsyourlast
πŸ“…︎ Dec 17 2019
🚨︎ report
A tale of 2 combustors reddit.com/gallery/jncj15
πŸ‘︎ 2
πŸ’¬︎
πŸ‘€︎ u/Brok3nBottle
πŸ“…︎ Nov 03 2020
🚨︎ report
Finally finished my first Kastelan Robot. I'm really happy with how the combustor turned out.
πŸ‘︎ 97
πŸ’¬︎
πŸ‘€︎ u/sadesomer
πŸ“…︎ Dec 12 2019
🚨︎ report
Combustor/Burner sizing

Hello all!

In the framework of our capstone project, we have a combustor burning primarily hydrogen and other hydrocarbons. We have to size the apparatus, ie find its precise dimensions. We tried considering it a PFR but the very rapid rate of the reaction (combustion) produces a very small volume. Anyone has an idea how to size a burner? Or maybe a relation between the flowrate in the burner and its dimensions? Thanks in advance!

πŸ‘︎ 2
πŸ’¬︎
πŸ‘€︎ u/spyrstel
πŸ“…︎ Jan 14 2021
🚨︎ report
Just realized that they gave the melee Kastellan a heavy phosphor and the shooty Kastellan an incendine combustor on the instruction booklet >:/ (also featuring my admech-themed nails)
πŸ‘︎ 17
πŸ’¬︎
πŸ“…︎ Jun 14 2020
🚨︎ report
Spontaneous combustors, what are some inconvenient times to burst into flames?
πŸ‘︎ 2
πŸ’¬︎
πŸ“…︎ Sep 26 2020
🚨︎ report
Combustor valus on Mercury quest item drop

Just wondering if this is happening for anyone else. Or if someone can repeat it. 4 of them dropped for me when I was in there. As far as I know I don't have any quests that needs a drop from here. Wondering if I'm bugged and supposed to get something. It reminds me of the corsair down from dreaming city.

https://preview.redd.it/d5gkp785a2v51.png?width=1920&format=png&auto=webp&s=c6459ceb34d4e6181bf45928a1f0f0315efb8a4b

πŸ‘︎ 3
πŸ’¬︎
πŸ‘€︎ u/zxgrimangelxz
πŸ“…︎ Oct 24 2020
🚨︎ report
Rockets are a thousand ton metal tube filled with diesel, powered by turbine driven diesel combustors and fly straight into space burning tons of the stuff per second. They are real life dieselpunk.
πŸ‘︎ 7
πŸ’¬︎
πŸ“…︎ Jun 16 2020
🚨︎ report
BUG! WANTED: Combustor Valus weekly bounty not completing even though I killed him.

Killed him twice, with a partner, and both times hasn't completed the bounty. However, it counts as a lost sector and adventure completion so the worst part is, the heroic adventure disappears off the map. I can't select it again. I abandoned and repurchased, and still, the adventure is gone from my map. Anyone else have this problem?

Edit: I ran again with a friend who had the adventure, and again, it didn’t pop for me.

Edit: Last night it randomly popped up again on Mercury and I was able to select it. I completed it solo, and it DID finally check off the bounty and I was rewarded. I'd go back and give it a second look y'all. Thanks for posting your experiences here.

Edit: For all attempts, I was a hammer titan.

πŸ‘︎ 89
πŸ’¬︎
πŸ‘€︎ u/swallja
πŸ“…︎ Sep 12 2018
🚨︎ report
Does the Deluxe Badass Combustor work past level 10?
πŸ‘︎ 7
πŸ’¬︎
πŸ‘€︎ u/clizzle32
πŸ“…︎ Sep 13 2019
🚨︎ report
I'm on a train and it's stopped because the combustor isn't working - no idea if anyone has any insight but the crew is not telling us anything

We stopped for 30 min before to try to fix it, we rode for another 15 min and now we're stopped again and they sent the crew over to try and fix it. Any idea how long this takes?? Sorry if this is not a good place to post this

πŸ‘︎ 8
πŸ’¬︎
πŸ“…︎ Sep 25 2019
🚨︎ report
IIT Madras: candle flame oscillators shine light on combustor stability thehindu.com/sci-tech/sci…
πŸ‘︎ 11
πŸ’¬︎
πŸ‘€︎ u/kimjongunthegreat
πŸ“…︎ Feb 14 2020
🚨︎ report
Coal Combustor (Pixel Dailies theme- Power Plant)
πŸ‘︎ 70
πŸ’¬︎
πŸ‘€︎ u/MirruTatep
πŸ“…︎ Jan 11 2020
🚨︎ report
Purdue - LOX/LCH4 single element combustor
πŸ‘︎ 32
πŸ’¬︎
πŸ‘€︎ u/OatLids
πŸ“…︎ Jun 02 2017
🚨︎ report
Composite based combustor

Hey guys I suddenly had an urge to look into this topic. Could anyone here suggest some reading material based on this. Also if you've got links to papers or research hope you share.
Thanks in advance!!!!

πŸ‘︎ 4
πŸ’¬︎
πŸ‘€︎ u/buffalosouljaboi
πŸ“…︎ Dec 07 2019
🚨︎ report
Wanted: Combustor Valus Bug?

Ran into a weird bug and wanted to see if anyone else is having similar issues. I picked up the weekly Spider bounty ("WANTED: COMBUSTOR VALUS") and completed it with a fireteam of 3 people. Strangely, only one of our fireteam members got credit for the completion while me and the other guy did not. This wouldn't be an issue if we could just do it again, however, the adventure icon on the minimap is gone now. I tried abandoning the bounty and purchasing it again but the minimap icon is still gone. Has anyone else seen this?

πŸ‘︎ 18
πŸ’¬︎
πŸ‘€︎ u/abzntmind3d
πŸ“…︎ Sep 11 2018
🚨︎ report
Is Wanted combustor valus bugged?

I completed it with other people and had bounty. It completed for everyone but me.

πŸ‘︎ 17
πŸ’¬︎
πŸ‘€︎ u/Squatting-Turtle
πŸ“…︎ Sep 12 2018
🚨︎ report

Please note that this site uses cookies to personalise content and adverts, to provide social media features, and to analyse web traffic. Click here for more information.